Buy, Order, Customize Dry type Electrical Transformers made in Canada online.
Wednesday, December 18, 2024
Log In

Log In

Forgot Your Password?

Cart Subtotal: US$ 0.00

Transformer Frequency

What is Transformer Frequency

The three common frequencies available are 50Hz, 60Hz and 400Hz. European power is typically 50Hz while North American power is usually 60hz. The 400 Hz is reserved for high-powered applications such as aerospace and some special-purpose computer power supplies and hand-held machine tools. Such high frequencies cannot be economically transmitted long distances, so 400 Hz power systems are usually confined to the building or vehicle.
The transformer cannot change the frequency of the supply. If the supply is 60Hz, the output will also be 60 Hz. In most parts of the Americas, it is typically 60Hz, and in the rest of the world it is typically 50Hz. Places that use the 50 Hz frequency tend to use 230 V RMS, and those that use 60Hz tend to use 117 V RMS.

The frequency of large interconnected power distribution systems is tightly regulated so that, over the course of a day, the average frequency is maintained at the nominal value within a few hundred parts per million. While this allows simple electric clocks, relying on synchronous electric motors, to keep accurate time, the primary reason for accurate frequency control is to allow the flow of alternating current power from multiple generators through the network to be controlled.
Frequency of the system will vary as load is added to the system or as generators are shut down; other generators are adjusted in speed so that the average system frequency stays nearly constant. During a severe overload caused by failure of generators or transmission lines, the power system frequency will decline. Loss of an interconnection carrying a large amount of power (relative to system total generation) will cause system frequency to rise. Special protection relays in the power system network sense the decline and may automatically initiate load shedding or tripping of interconnection lines, to preserve the operation of at least part of the network. Quite small frequency deviations, on the order of 0.5 Hz on a 50 Hz or 60 Hz network, will result in automatic load shedding or other control actions to restore system frequency. Smaller power systems, not extensively interconnected with many generators and loads, may not maintain frequency with the same degree of accuracy.

50 Hz vs. 60 Hz Power Transformers
More iron and/or more turns of wire are required to have the same transformer winding inductive reactance at a 50Hz frequency. As a result, power transformers designed for use in U.S. 60Hz applications run very hot, and sometimes extremely hot, if used in 50Hz power mains, even if they have windings to accommodate the higher voltages. Iron-core and copper-wire both cost money and take physical space, so transformer designers generally use no more of either than necessary to keep power losses reasonable at an intended operating frequency.
One of the most common questions is "what will happen if I plug my 60Hz dryer, heater into a 50Hz outlet?" The most likely answer is "it depends." If the appliance is not motorized, there may be no noticeable affect. Otherwise:
    What happens if you connect a 60Hz motor to a 50 Hertz mains:
  • The motor turns 17% slower
  • The internal current goes up by 17%
  • The power (watt) goes down with 17 %
  • The mechanical cooling is less, because of 17% less turns
The result is a higher current, then designed by the manufacturer and the insulation of the electrical wiring deteriorate much quicker, which after sometime results in a burn-out. A dryer has a heating element and a motor, the heating element is not a problem, but the motor is made for 60Hz, can be burned-out. Solutions: You can use a transformer to solve part (the internal current can be lowered but the cycles cannot be changed) of the problem, by connecting the 60 cycles apparatus to a voltage 20% lower as mentioned on the nameplate. So a 240volt 60Hz apparatus can be connected to a 50Hz mains on a voltage 20% lower then 240volt = 190 volt. Electrical Equipment Electrical equipment is made by the manufacturer for a certain amount of Current, Voltage and Hertz (Cycles) which is mentioned on the name plate. The Current is dependent of the Voltage and the Hertz. If the Current through the apparatus is higher then is designed for because of connecting it to a Voltage or Hertz other then stated on the nameplate, the apparatus burns out and can cause a fire. The electrical current is dependent of the Voltage and the Hertz you cannot connect electrical equipment with a motor and or transformer in it, to a Voltage other then stated on the nameplate. If you connect 60 Hertz equipment to a 50Hz mains the internal current goes up with 17% and can cause a burn-out. If you connect 120 Volt equipment to 220 Volt the current goes up with 100% and surely causes a fast burn-out. This means even if the Voltage is the same, or if you put a transformer in between to transform the Voltage, you still cannot connect a 60Hz motor or equipment with an internal input transformer to a 50Hz mains.

  • Go back to the previous page.
  • Use the search bar at the top of the page to search for your products.
  • Follow these links to get you back on track!
    Store Home | My Account

Transformer Calculator

Help: To calculate required kVA of the transformer enter Load Amps, Load Volt and press "Required kVA" button. Also you can calculate Current from other two parameters.
Note: Recommended add up to 20% to the calculated kVA